AC High Voltage Test Sets for GIS
● Transformer
● GIS system
● SF6 switchgear
● Cables
● Bushing
● Insulator
● CT/PT
● Other capacitive devices
● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable.
● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate.
● With 220V or 380V single phase power, convenient for on-site power sourcing.
● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective.
● Rated output voltage: based on different test objects.
● Output frequency: 20- 300Hz.
● Waveform: pure sine wave, THD <1.0%.
● Max. capacity: 1000kVA and below.
● Duty Cycle: Continuous working time 15mins one time at full power output. (or customer demand.)
● Frequency adjustment sensitivity: 0.1Hz, instability <0.05%.
● Power Supply: 380/220V ± 15%/50Hz ± 5%.
| 
 GDTF-108/108  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-108  | 
| 
 Capacity (kVA)  | 
 108  | 
| 
 Application scope  | 
 31500kVA or below  | 
| 
 35kV power transformer  | 
|
| 
 35kV circuit breaker and bus bar, insulators  | 
|
| 
 10kV (300 mm²) cable 2000m  | 
|
| 
 35k V (300 mm²)cable 500m  | 
|
| 
 Main configurations  | 
 5kW Variable frequency source 1 set  | 
| 
 5kVA Exciting transformer 1 set  | 
|
| 
 Reactors 27kV/1A 4sets  | 
|
| 
 Capacitive divider 100kV  | 
|
| 
 GDTF-216/216  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-216  | 
| 
 Capacity (kVA)  | 
 216  | 
| 
 Application scope  | 
 110kV Circuit breaker and bus bar  | 
| 
 110kV GIS  | 
|
| 
 35kV(300 mm²) cable 1500m  | 
|
| 
 10kV(300 mm²) cable 3km  | 
|
| 
 110kV full insulation Transformer  | 
|
| 
 Main configurations  | 
 10kW Variable frequency source 1 set  | 
| 
 10kVA Exciting transformer 1 set  | 
|
| 
 Reactors 54kV/1A 4sets  | 
|
| 
 Capacitive divider 200kV  | 
|
| 
 GDTF-270/270  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-270  | 
| 
 Capacity (kVA)  | 
 270  | 
| 
 Application scope  | 
 110kV GIS and transformer  | 
| 
 110kV GIS and transformer  | 
|
| 
 35kV (300 mm²) cable 2km  | 
|
| 
 Main configurations  | 
 15kW Variable frequency source 1 set  | 
| 
 15kVA Exciting transformer 1 set  | 
|
| 
 Reactors 54kV/1A 5sets  | 
|
| 
 Capacitive divider 300kV  | 
|
| 
 GDTF-400/400  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-400  | 
| 
 Capacity (kVA)  | 
 400  | 
| 
 Application scope  | 
 220kV GIS and transformer  | 
| 
 10kV (300 mm²) cable 4km  | 
|
| 
 35kV (300 mm²) cable 1km  | 
|
| 
 Main configurations  | 
 20kW Variable frequency source 1 set  | 
| 
 20kVA Exciting transformer 1 set  | 
|
| 
 Reactor   | 
|
| 
 Capacitive divider 400kV  | 
|
| 
 GDTF-520/260  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-260  | 
| 
 Capacity (kVA)  | 
 520  | 
| 
 Application scope  | 
 110KV Circuit breaker and bus bar  | 
| 
 110kV GIS  | 
|
| 
 110kV (300 mm²) cable 800m  | 
|
| 
 35kv (300 mm²) cable 3km  | 
|
| 
 10kV (300 mm²) cable 6km  | 
|
| 
 110kv full insulation Transformer  | 
|
| 
 Main configurations  | 
 25kW Variable frequency source 1 set  | 
| 
 25kVA Exciting transformer 1 set  | 
|
| 
 Reactor 65kV/2A 4sets  | 
|
| 
 Capacitive divider 300kV  | 
|
| 
 GDTF-500/500  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-500  | 
| 
 Capacity (kVA)  | 
 500  | 
| 
 Application scope  | 
 220kV or below CT/PT  | 
| 
 220kV or below bushing  | 
|
| 
 220kV or below Insulators, disconnectors  | 
|
| 
 220kV or below Circuit breaker  | 
|
| 
 220kV or below Insulation Instrument  | 
|
| 
 Main configurations  | 
 20kW Variable frequency source 1 set  | 
| 
 20kVA Exciting transformer 1 set  | 
|
| 
 Reactor 125kV/1A 4sets  | 
|
| 
 Capacitive divider 500kV  | 
|
| 
 GDTF-600/600  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-600  | 
| 
 Capacity (kVA)  | 
 600  | 
| 
 Application scope  | 
 110kV (300 mm²) cable 800m  | 
| 
 35kv (300 mm²) cable 110m  | 
|
| 
 35-220kV GIS, transformers, insulators  | 
|
| 
 Main configurations  | 
 30kW Variable frequency source 1 set  | 
| 
 30kVA Exciting transformer 1 set  | 
|
| 
 Reactor 120kV/1A 5sets  | 
|
| 
 Capacitive divider 600kV  | 
|
| 
 GDTF-800/800  | 
|
| 
 Input voltage (V)  | 
 380  | 
| 
 Output voltage (kV)  | 
 0-800  | 
| 
 Capacity (kVA)  | 
 800  | 
| 
 Application scope  | 
 110kV (300 mm²) cable 800m  | 
| 
 220kv (300 mm²) cable 500m  | 
|
| 
 35-500kV GIS, transformers, insulators  | 
|
| 
 Main configurations  | 
 40kW Variable frequency source 1 set  | 
| 
 40kVA Exciting transformer 1 set  | 
|
| 
 Reactor 200kV/1A 4sets  | 
|
| 
 Capacitive divider 800kV  | 
|
				        